QuantiChrom™Hydroxyproline Assay Kit

Referência DHYP-100

Tamanho : 100tubes

Marca : BioAssay Systems

Solicitar mais informações

Contactar o distribuidor local :


Telefone : +1 850 650 7790

QuantiChrom™ Hydroxyproline Assay Kit



Application

  • For quantitative determination of hydroxyproline and collagen in biologic and cosmetic samples.

Key Features

  • Safe. Our hydroxyproline assay uses an improved perchlorate-free chemistry.
  • Sensitive and accurate. Uses 20 µL sample. Linear detection range 0.5 µg/mL to 50 µg/mL hydroxyproline in 96-well plate assay.
  • Convenient. Collagen can be hydrolyzed in Eppendorf tubes, and final incubation can be performed at 37°C.

Method

  • OD560nm

Samples

  • Hydroxyproline and collagen in biologic and cosmetic samples

Species

  • All

Procedure

  • Approx. 2 hrs

Size

  • 100 Tests

Detection Limit

  • 0.5 µg/mL

Shelf Life

  • 12 months

More Details

HYDROXYPROLINE is a unique modified amino acid that is found exclusively in several animal proteins, the most prevalent of which is collagen. Collagen is a key structural protein of the extracellular matrix and is common in connective tissues due to its incredible strength. Because of its role as a key structural protein in animals collagen is crucial for many medical applications, such as tissue transplantation and scaffolding for complex cell cultures. Collagen is also used in the beauty industry, as it can be supplemented to increase tissue rigidity, resulting in skin that appears more youthful. BioAssay Systems’ Hydroxyproline assay kit delivers a safe, simple, and sensitive means to quantify hydroxyproline in samples. In the first step of this procedure, hydroxyproline in the sample is oxidized to a pyrrole ring. This compound then reacts with a dye reagent to yield a pink product that can be measured at 560 nm. Hydroxyproline exists almost exclusively in collagen, so hydroxyproline content can be used as a proxy for collagen content.

How do I hydrolyze solid collagen samples(cartilage, tendon, etc.)?

Dessicate sample in a drying oven until all water has been removed(Can measure wet weight, but dry is more accurate). Add 50 µL 10N NaOH for every 150 mg of sample to be hydrolyzed in an Eppendorf tube. Heat in a heat block at 100°C for 1-2 hours. Allow tube to cool. Add equivalent 10N HCl to neutralize NaOH. Add a volume of deionized water equal to the amount of NaOH and HCl added. (A detailed hydrolysis procedure is in the product datasheet).

Do I need to hydrolyze the hydroxyproline standard?

We have found that the hydroxyproline standards and blank are very similar whether or not they undergo hydrolysis. Therefore, the kit does not require hydrolysis treatment of the hydroxyproline standard.

Can I run the final incubation at a different temperature?

The incubation can be set to 45°C for 50 minutes. The protocol states to use 37°C because then it can be run in a plate reader or a tissue culture incubator. Some plate readers may not heat to 45°C.

No citations for this new product. Please check back later. You may click here to check if citations are available, but are not listed here yet.

If you or your labs do not have the equipment or scientists necessary to run this assay, BioAssay Systems can perform the service for you.

– Fast turnaround
– Quality data
– Low cost

Hydroxyproline assay kit
Catalog No: DHYP-100 Categories Food & Beverage Analysis, Metabolism Tags DHYP-100, Food & Beverage Analysis, Hydroxyproline assay kits, Hydroxyproline determination kits, Hydroxyproline measurement kits, Hydroxyproline test kits, metabolism, QuantiChrom Hydroxyproline Assay Kits, QuantiChromTM Hydroxyproline Assay Kit

Você também pode estar interessado nos seguintes produtos:



Referência
Descrição
Cond.
Price Bef. VAT
CAK1067
 100Assays 
STA-675
 96assays