Size | |
---|---|
96T | Inquiry |
48T | Inquiry |
- Product Name
- Human Anti-MPV IgM(Anti-Monkeypox Virus IgM) ELISA Kit
- Alias
- MPXV IgM ELISA Kit, Monkeypox virus IgM ELISA Kit
- Catalogue No.
- EH4997
- Size
- 48T/96T
- Species
- Human
- Sample Type
- Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples
- Detection Method
- indirect elisa
- Detection Wavelength
- OD450
- Reaction Duration
- 3 hours
- Range
- 1.563-100ng/ml
- Sensitivity
- 0.938ng/ml
- Storage
- 2-8°C(Sealed), Don't cryopreserve.
- Specificity
- Specifically binds with Anti-MPV IgM , no obvious cross reaction with other analogues.
- Required Instruments and Reagents
-
- Microplate reader (wavelength: 450nm)
- 37°C incubator (CO2 incubator for cell culture is not recommenced.)
- Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
- Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
- Sterile tubes and Eppendorf tubes with disposable tips
- Absorbent paper and loading slot
- Deionized or distilled water
- Standard Curve
-
This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.)
Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.
- Recovery
-
Add a certain amount of Anti-MPV IgM into the sample. Calculate the recovery by comparing the measured value with the expected amount of Anti-MPV IgM in the sample.
Sample Type Recovery Range(%) Average(%) serum(n=10) 97-105 99 EDTA plasma(n=10) 95-104 98 Heparin plasma(n=10) 96-99 97 - Linearity
-
Dilute the sample with a certain amount of Anti-MPV IgM at 1:2, 1:4 and 1:8 to get the recovery range.
Sample Type 1:2 1:4 1:8 serum(n=10) 93-105% 93-99% 91-100% EDTA plasma(n=10) 89-102% 89-101% 90-99% Heparin plasma(n=10) 93-102% 89-98% 91-100% - Precision(%)
-
Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.
Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.
Item Intra-assay Precision Inter-assay Precision Sample 1 2 3 1 2 3 n 20 20 20 20 20 20 Mean (ng/ml) 3.18 11.3 47.28 3.1 11.72 48.59 Standard deviation 0.15 0.45 2.42 0.17 0.62 2.27 CV(%) 4.66 3.95 5.12 5.43 5.31 4.68 - Stability
-
Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.
ELISA kit(n=5) 37°C for 1 month 2-8°C for 6 months Average(%) 80 95-100