Horse TF (Tissue Factor) ELISA Kit

Referencia EHS0044

embalaje : 96T

Marca : FineTest

Solicitar más información

Contact local distributor :


Teléfono : +1 850 650 7790

  • SPECIFICATIONS
  • FIGURES
  • CONDITIONS
Product Name
Horse TF(Tissue Factor) ELISA Kit

Alias
TF ELISA Kit, Tissue factor ELISA Kit, F3 ELISA Kit, FIII ELISA Kit, CD142 ELISA Kit, TFA ELISA Kit, Thromboplastin ELISA Kit, Coagulation Factor III ELISA Kit

Catalogue No.
EHS0044

Size
48T/96T

Species
Horse

UniProt ID
F6UIK6

Sample Type
Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples

Detection Method
Sandwich ELISA, Double Antibody

Detection Wavelength
OD450

Reaction Duration
4 hours

Range
7.813-500pg/ml

Sensitivity
4.688pg/ml

Storage
2-8 , no obvious cross reaction with other analogues.

ELISA Kit Components
Kit Components Item Size(48T) Size(96T) Storage Condition for Opened Kit
E001 ELISA Microplate(Dismountable) 8×6 8×12 Put the rest strips into a sealed foil bag with the desiccant. Stored for 1 month at 2-8 month at -20 Lyophilized Standard 1vial 2vial Put the rest standards into a desiccant bag. Stored for 1 month at 2-8 month at -20 Biotin-labeled Antibody(Concentrated, 100X) 60ul 120ul 2-8 HRP-Streptavidin Conjugate(SABC, 100X) 60ul 120ul
E024 TMB Substrate 5ml 10ml
E039 Sample Dilution Buffer 10ml 20ml 2-8 Antibody Dilution Buffer 5ml 10ml
E049 SABC Dilution Buffer 5ml 10ml
E026 Stop Solution 5ml 10ml
E038 Wash Buffer(Concentrated, 25X) 15ml 30ml
E006 Plate Sealer 3 pieces 5 pieces  
E007 Product Description 1 copy 1 copy

Required Instruments and Reagents
  1. Microplate reader (wavelength: 450nm)
  2. 37 incubator for cell culture is not recommenced.)
  3. Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
  4. Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
  5. Sterile tubes and Eppendorf tubes with disposable tips
  6. Absorbent paper and loading slot
  7. Deionized or distilled water

Assay Procedure Summary
Elisa实验原理图
  • Step 1: Add 100ul standard or sample into each well, seal the plate and statically incubate for 90 minutes at 37: Add 100ul biotin-antibody working solution, seal the plate and statically incubate for 60 minutes at 37min each time.
  • Step 3: Add 100ul HRP-Streptavidin Conjugate (SABC) working solution, seal the plate and statically incubate for 30 minutes at 37min each time.
  • Step 4: Add 90ul TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37: Add 50ul stop solution. Read at 450nm immediately and calculate.

Standard Curve

This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18min at 37;margin-bottom: 0.5rem;">Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.

STD.(pg/ml) OD-1 OD-2 Average
0 0.131 0.135 0.133
7.813 0.18 0.186 0.183
15.625 0.208 0.214 0.211
31.25 0.265 0.273 0.269
62.5 0.429 0.441 0.435
125 0.738 0.76 0.749
250 1.402 1.442 1.422
500 2.484 2.556 2.52
EHS0044 Standard Curve Image

Recovery

Add a certain amount of TF/F3 into the sample. Calculate the recovery by comparing the measured value with the expected amount of TF/F3 in the sample.

Sample Type Recovery Range(%) Average(%)
serum(n=10) 88-104 98
EDTA plasma(n=10) 86-98 91
Heparin plasma(n=10) 87-105 96

Linearity

Dilute the sample with a certain amount of TF/F3 at 1:2, 1:4 and 1:8 to get the recovery range.

Sample Type 1:2 1:4 1:8
serum(n=10) 88-104% 85-101% 87-104%
EDTA plasma(n=10) 82-89% 84-99% 82-98%
Heparin plasma(n=10) 80-96% 85-100% 80-99%

Precision(%)

Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.

Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.

Item Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean (pg/ml) 16.01 62.66 250.9 15.74 64.58 246.6
Standard deviation 0.86 3.39 14.83 0.84 3.47 13.17
CV(%) 5.36 5.41 5.91 5.32 5.37 5.34

Stability

Perform the stability test for the sealed kit at 37-8) 37 month 2-8 months Average(%) 80 95-100