Canine Estrogen ELISA Kit

Referência ECA0024

Tamanho : 96T

Marca : FineTest

Solicitar mais informações

Contactar o distribuidor local :


Telefone : +1 850 650 7790

  • SPECIFICATIONS
  • FIGURES
  • CONDITIONS
Product Name
Canine Estrogen (Estrogen) ELISA Kit

Alias
Es ELISA Kit, Estrogen ELISA Kit

Catalogue No.
ECA0024

Size
48T/96T

Species
Canine

UniProt ID
50-28-2 53-16-7 50-27-1

Sample Type
Serum, Plasma, Cell Culture Supernatant, cell or tissue lysate, Other liquid samples

Detection Method
Competitive ELISA, Coated with Antigen

Detection Wavelength
OD450

Reaction Duration
2 hours

Range
15.625-1000pg/ml

Sensitivity
9.375pg/ml

Storage
2-8T) Size(96T) Storage Condition for Opened Kit E001 ELISA Microplate(Dismountable) 8×6 8×12 Put the rest strips into a sealed foil bag with the desiccant. Stored for 1 month at 2-8 month at -20 Lyophilized Standard 1vial 2vial Put the rest standards into a desiccant bag. Stored for 1 month at 2-8 month at -20 Lyophilized Biotin-labeled Antibody(Concentrated) 1vial 1vial E034 HRP-Streptavidin Conjugate(SABC, 100X) 60ul 120ul 2-8 TMB Substrate 5ml 10ml E005 Purified Water 200ul 200ul 2-8 Sample Dilution Buffer 10ml 20ml E040 Antibody Dilution Buffer 5ml 10ml E049 SABC Dilution Buffer 5ml 10ml E026 Stop Solution 5ml 10ml E038 Wash Buffer(Concentrated, 25X) 15ml 30ml E006 Plate Sealer 3 pieces 5 pieces   E007 Product Description 1 copy 1 copy

Required Instruments and Reagents
  1. Microplate reader (wavelength: 450nm)
  2. 37 incubator for cell culture is not recommenced.)
  3. Automated plate washer or multi-channel pipette/5ml pipettor (for manual washing purpose)
  4. Precision single (0.5-10μL, 5-50μL, 20-200μL, 200-1000μL) and multi-channel pipette with disposable tips(Calibration is required before use.)
  5. Sterile tubes and Eppendorf tubes with disposable tips
  6. Absorbent paper and loading slot
  7. Deionized or distilled water

Assay Procedure Summary
Elisa实验原理图
  • Step 1: Wash the plate twice before adding the standard and sample.
  • Step 2: Add 50ul standard or sample into each well. Immediately add 50ul biotin-labeled antibody working solution into each well(The tip can't be reused after touching the liquid.), gently shake the plate for 1min, seal closely and statically incubate for 45 minutes at 37min each time.
  • Step 3: Add 100ul HRP-Streptavidin Conjugate (SABC) working solution into each well, seal the plate and statically incubate for 30 minutes at 37min each time.
  • Step 4: Add 90ul TMB substrate solution, seal the plate and statically incubate for 10-20 minutes at 37: Add 50ul stop solution. Read at 450nm immediately and calculate.

Standard Curve

This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18min at 37;margin-bottom: 0.5rem;">Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.

STD.(pg/ml) OD-1 OD-2 Average
0 2.242 2.308 2.275
15.625 1.853 1.907 1.88
31.25 1.413 1.455 1.434
62.5 0.957 0.985 0.971
125 0.648 0.666 0.657
250 0.438 0.45 0.444
500 0.263 0.271 0.267
1000 0.164 0.168 0.166
ECA0024 Standard Curve Image

Recovery

Add a certain amount of Estrogen into the sample. Calculate the recovery by comparing the measured value with the expected amount of Estrogen in the sample.

Sample Type Recovery Range(%) Average(%)
serum(n=10) 85-103 97
EDTA plasma(n=10) 91-105 94
Heparin plasma(n=10) 85-95 96

Linearity

Dilute the sample with a certain amount of Estrogen at 1:2, 1:4 and 1:8 to get the recovery range.

Sample Type 1:2 1:4 1:8
serum(n=10) 92-98% 90-101% 83-100%
EDTA plasma(n=10) 82-96% 86-99% 85-101%
Heparin plasma(n=10) 86-99% 81-98% 90-95%

Precision(%)

Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate.

Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.

Item Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean (pg/ml) 30.85 124.1 494 31.38 127.5 502
Standard deviation 1.46 6.4 25.14 1.47 6.4 23.39
CV(%) 4.73 5.16 5.09 4.7 5.02 4.66

Stability

Perform the stability test for the sealed kit at 37-8) 37 month 2-8 months Average(%) 80 95-100